Single-Phase Smart Round Meter
ANSI Standard Single-Phase/Two-Phase Smart Meter (FM1S FM2S FM12S)
Product Description
The HXS100-A is a new generation single-phase and two-phase smart ANSI meter, covering FM1S, FM2S, and FM12S connection types. It complies with ANSI C12.1 and ANSI C12.20 standards for Class CA0.5 or CA0.2 accuracy. This smart meter can be optionally equipped with public network, RF Mesh, or PLC communication modules, enabling remote connection to an AMI system for remote energy monitoring and meter reading control.

Product Advantages
Precision Metering
ANSI C12.1 – Accuracy Class CA0.5 or CA0.2, Time-of-Use Rates, Reactive Energy Metering and Power Quality Monitoring, Load Profile, Maximum Demand Storage, Event Logging.

Flexible Communication
Multiple remote communication modules available: Public Network Module / RF Mesh Module / PLC Module, with open communication protocols DLMS or ANSI C12.19.

Intelligent Management
Tamper Detection, Remote Relay Control, 100A or 200A optional. Demand Reset: Remote or Manual.

Single-Phase Smart Round Meter
HXS100-A
HXS100-A
| Accuracy Class | Active Energy CA0.5 or CA0.2 (ANSI) | |
| Reactive Energy Class 2 (IEC) | ||
| Voltage | Rated Voltage | 120V-240V |
| Operating Voltage Range | 0.8Un-1.2Un | |
| Current | Current Range | 15(100)A |
| 30(200)A | ||
| Creeping | No more than one pulse recorded during creeping time, compliant with ANSI C12.1 | |
| 0.000A | ||
| Starting | 50mA for CL100 | |
| 100mA for CL200 | ||
| Frequency | 50/60Hz ± 5% | |
| Temperature | Operating Temperature | -40℃ to +70℃ |
| Storage and Transport Limit Temperature | -40℃ to +85℃ | |
| Humidity | 0% to 100% Non-condensing | |
| Battery | Operating Life | 15 Years |
| Power Consumption | Voltage Circuit (Active) | ≤1 W |
| Voltage Circuit (Apparent) | ≤4 VA | |
| Current Circuit | ≤0.5 VA | |
| Dielectric Strength | AC Voltage Test | 4kV 1min |
| Impulse Voltage Test | 1.2/50µs 6kV | |
| EMC | Electrostatic Discharge (Contact Discharge) | 8kV |
| Electrostatic Discharge (Air Discharge) | 15kV | |
| Surge | 6kV | |
| Up to 10kV (Optional) | ||
| Electrical Fast Transient/Burst | 4kV | |
| Radiated RF Electromagnetic Field Immunity (80MHz to 2000MHz) | 10V/m (with current), 30V/m (without current) | |
| Protection | IP Rating | UL50, IP54 |
| Cover | Transparent PC | |
| Base | Opaque PC + Fiberglass | |
| UV Resistance | UV 72 1000 hours, IEC 62052-11 6.3.4 | |
| Installation Environment | Indoor/Outdoor | |
| LCD Display | Character Size | 4.90mm x 11.43mm |
| Number of Characters | 7 | |
| Weight | Net Weight | Approx. 1.58kg (with relay) |
| Approx. 1.2kg (without relay) | ||
| Dimensions | 177mm×177mm×160.5mm | |
| Operating Life | >15 Years |



