Consult Now

Metal Low-Voltage Integrated Distribution Box

The low-voltage integrated distribution box is a low-voltage distribution device integrating power distribution, metering, protection, control, and reactive power compensation, mainly used in power systems for industrial, commercial, and residential buildings.

Product Description

The low-voltage integrated distribution box features safety and reliability, flexibility and variety, high efficiency and energy saving, easy maintenance, and automated management.

Product Advantages

Metal Low-Voltage Integrated Distribution Box

BXJP.R010
 Surge SwitchTGB1N-63, 4P, C63, Breaking Capacity 6 kA
 Surge Protective DeviceTGDY551-15, 385 V, 4P (Xiangyun 3.0), 385 V, 20 kA
 Measuring/Metering CTBH-0.66, 50, 800/5, Class 0.5S
 Capacitor Cabinet MCCBTGM1-250L3300, 160 A
 Smart Capacitor (Common Compensation)WX-ICH-GB/450M-10S.10S
 Smart Capacitor (Phase Compensation)WX-ICH-FB/250M-20F
Main Incoming SwitchFuse Disconnect SwitchHR6-400/30, 400 A (Temperature Rise & Short-Time Withstand Model)
Outgoing SwitchMCCBTGM2LC-400L/3P+N, 400 A, LCD Type (Temperature Rise Special)
 MCCBTGM2LC-250L/3P+N, 250 A, LCD Type (Temperature Rise Special)
 Product Dimensions (W x D x H)1350 x 700 x 1200 mm
 Surge SwitchTGB1N-63, 4P, C63, Breaking Capacity 6 kA
 Surge Protective DeviceTGDY551-15, 385 V, 4P (Xiangyun 3.0), 385 V, 20 kA
 Measuring/Metering CTBH-0.66, 50, 800/5, Class 0.5S
 Capacitor Cabinet MCCBTGM1-250L3300, 250 A
 Smart Capacitor (Common Compensation)WX-ICH-GB/450M-10S.10S
 Smart Capacitor (Phase Compensation)WX-ICH-FB/250M-20F
Main Incoming SwitchFuse Disconnect SwitchHR6-800/30, 800 A (Temperature Rise & Short-Time Withstand Model)
Outgoing SwitchMCCBTGM2LC-400L/3P+N, 800 A, LCD Type (Temperature Rise Special)
 MCCBTGM2LC-250L/3P+N, 400 A, LCD Type (Temperature Rise Special)
 Product Dimensions (W x D x H)1350 x 700 x 1200 mm
 Surge SwitchEx9BH, 3P, D63, HZ
 Surge Protective DeviceEx9ue1+2, 12.5, 385, 3PN
 Current TransformerEH-0.66, 40, 400/5, 0.5S
 Capacitor MCCBEX9MIN, TM, 125, 3P, HZ
 Smart Capacitor (Common Compensation)CRC-CS-450-10/10-A-G
 Smart Capacitor (Phase Compensation)CRC-CF-250-21-A-G
Main Incoming SwitchFuse Disconnect SwitchEx9IRT-400/31, 400 A
Outgoing SwitchMCCBEA3-6D/400 A/4P, 800 mA
 Smart Fault Detection DeviceQL-CWEC1
 Semiconductor Cooling Air ConditionerDTAI-W200V24
 Smart Door LockLBLZ-57
 Product Dimensions (W x D x H)1350 x 700 x 1200 mm
 Surge SwitchEx9BH, 3P, D63, HZ
 Surge Protective DeviceEx9ue1+2, 12.5, 385, 3PN
 Current TransformerEH-0.66, 40, 800/5, 0.5S
 Capacitor MCCBEx9M2N, TM, 250, 3P, HZ
 Smart Capacitor (Common Compensation)CRC-CS-450-15/15-A-G
 Smart Capacitor (Phase Compensation)CRC-CF-250-30-A-G
Main Incoming SwitchFuse Disconnect SwitchEx9IRT-630/31, 630 A
Outgoing SwitchMCCBEA3-6D/630 A/4P, 800 mA
 Smart Fault Detection DeviceQL-CWEC1
 Semiconductor Cooling Air ConditionerDTAIW200V24
 Smart Door LockLBLZ-57
 Product Dimensions (W x D x H)1350 x 700 x 1200 mm

Success Stories

Search

How Hexing Electrical Uses Cookies and Similar Technologies

To ensure the normal operation of the website, we sometimes store small data files called cookies on computers or mobile devices. A cookie is a plain text file stored on a computer or mobile device by a web server. The content of a cookie can only be retrieved or read by the server that created it. Each cookie is unique to your web browser or mobile application. Cookies typically contain identifiers, site names, and some numbers and characters. With the help of cookies, websites can store data such as user preferences or items in a shopping cart.

The purpose of Hexing Electrical enabling cookies is the same as that of most websites or internet service providers, which is to improve the user experience. With the help of cookies, websites can remember a user’s single visit (using session cookies) or multiple visits (using persistent cookies). With the help of cookies, websites can save settings such as language, font size, and other browsing preferences for a computer or mobile device. This means that users do not need to reconfigure their preferences each time they visit. If a website does not use cookies, it will treat the user as a new visitor every time they open a webpage. For example, if you log into a website and then go to another page, the website will not recognize you, and you will be logged out again. Hexing Electrical does not use cookies for any purpose other than those described in this policy. You can manage or delete cookies according to your preferences. For more details, please see AboutCookies.org. You can clear all cookies saved on your computer, and most web browsers have the function to block cookies. However, if you do this, you will need to change your user settings manually each time you visit our website. For more information on how to change browser settings, please visit the relevant help page of your browser.

In addition to cookies, we also use other similar technologies such as web beacons and pixel tags on our website. For example, emails sent to you by Hexing Electric may contain click URLs that link to content on the Hexing Electric website. If you click on such a link, Hexing Electric will track that click to help us understand your product and service preferences and improve customer service. A web beacon is typically a transparent image embedded in a website or email. With the help of pixel tags in emails, we can determine whether an email has been opened. If you do not wish your activity to be tracked in this way, you can unsubscribe from Hexing Electric’s mailing list at any time.

Your use of our website means you agree to the use of cookies, web beacons, and pixel tags as described above.