G3 Centralized Metering Box – Metering Unit
Plug-in Smart Meter
Product Description
The HXP200 is designed for the G3 series centralized metering devices, suitable for residential users, including 1P2W or 1P3W configurations.

Product Advantages
Metering
Total active energy, instantaneous values.

Event Logging
Multiple event detection and recording, including grid, relay, and overload events.

Prepayment
Switchable between prepaid and postpaid modes, emergency threshold, and supply of a certain amount of electricity after the user's balance is exhausted.

Load Control
Configurable overload threshold, remote connect/disconnect relay.

G3 Centralized Metering Box – Metering Unit
HXP200
HXP200
| Application | Direct-Connected | |
| Accuracy | Class 1 | |
| Rated Voltage | 1P2W | 120V |
| 1P3W | 240V | |
| Operating Voltage Range | 80%-120% | |
| Current | Base Current | 10A |
| Maximum Current | 100A | |
| Starting Current | ≤0.4%Ib | |
| Frequency | 50Hz or 60Hz | |
| Temperature | Operating Temperature | -25℃~60℃ |
| Storage & Transport Temp. Range | -40℃~70℃ | |
| Humidity | 95% | |
| Power Consumption | Voltage Circuit (Active) | ≤2W |
| Voltage Circuit (Reactive) | ≤10VA | |
| Current Circuit | ≤1 VA | |
| Dielectric Strength | AC Voltage Test | 4kV for 1 minute |
| Impulse Voltage Test | 1.2/50µs 6kV | |
| EMC | Electrostatic Discharge (Contact Discharge) | 8 kV |
| Electrostatic Discharge (Air Discharge) | 15 kV | |
| Surge Immunity Test | 4 kV | |
| Electrical Fast Transient/Burst Test | 4 kV | |
| Radiated RF Electromagnetic Field Immunity Test (80MHz to 2000MHz) | 10V/m (with load), | |
| 30V/m (without load) | ||
| IP Rating | IP51 | |
| Standards | IEC62052-11, IEC62053-21, IEC62055-41, IEC62055-51 | |
| Weight | Net Weight | Approx. 0.405 kg (1P3W) |
| Approx. 0.305 kg (1P2W) | ||
| Cable Outlets | Diameter 9 mm | |
| Dimensions | 155.7mm × 127.4mm × 37mm (L × W × H) |