Commercial & Industrial Ultrasonic Water Meter
Multi-path, high-precision ultrasonic metering technology.
Product Description
The HXW310 Commercial and Industrial (C&I) Ultrasonic Water Meter is designed for precise measurement and custody transfer at critical nodes within urban water distribution networks and District Metering Areas (DMAs). It facilitates water balance analysis and water loss monitoring for utilities, effectively mitigating Non-Revenue Water (NRW). This series supports a wide range of IoT communication technologies and adapts flexibly to diverse installation scenarios, providing water utilities with an impactful tool to advance smart water management.

Product Advantages
Slip-On Flange
Enables easy on-site installation.

No Moving Mechanical Parts
Zero wear and tear, ensuring long-term stability and reliability.

CBB Modular Structure Design
Enables rapid module replacement under all environmental conditions.

IP68 Ingress Protection
Suitable for long-term continuous underwater operation.

Drip and Empty Pipe Detection
High metering accuracy to meet network leakage monitoring requirements.

Multiple Communication Modes
Integrates pressure monitoring and temperature measurement functions.

Commercial & Industrial Ultrasonic Water Meter
HXW310
Technical Specifications
| Performance | Technical Specifications |
| Nominal Diameter | DN50-DN600 |
| Standards | GB/T 778-2018, JJG 162-2019 (ISO 4064, MID, OIML R 49) |
| Accuracy Class | Class 2 |
| Pressure Loss | Δp16 |
| Maximum Allowed Pressure | 1.6 MPa |
| Overall Volume Resolution | 0.00001 ~ 999999999.99999 m³ |
| Operating Environment | Temperature: -25 ~ 55 °C, Humidity ≤100% (RH) |
| Temperature Class | T50 |
| Flow Profile Sensitivity Class | U0D0 |
| Environmental Class | Class O |
| Electromagnetic Class | Class E2 |
| Power Supply | 3.6 V Lithium Battery, 10-Year Life |
| IP Rating | IP68 |
| Structure | Material: Stainless Steel, Cast Iron; Connection: Flange Connection |
| Acoustic Paths | Dual Path, Quad Path (Optional) |
| Storage Function | Hourly Water Use Log: 14 Days; Daily Total Log: 366 Days; Monthly Total Log: 72 Months |
| Communication | 1. M-Bus 2. RS485 3. Pulse 4. NB-IoT 5. 4-20 mA 6. GPRS |
Product Performance
| Nominal Diameter (mm) | R Ratio | Overload Flow Q4 (m³/h) | Permanent Flow Q3 (m³/h) | Transitional Flow Q2 (L/h) | Minimum Flow Q1 (L/h) | Starting Flow (L/h) | Minimum Reading (m³) | Maximum Reading (m³) |
| DN50 | 160/200/250/400/500 | 78.75 | 63 | 201.6 | 126 | 7 | 0.00001 | 999999999.99999 |
| DN65 | 160/200/250/400/500 | 78.75 | 63 | 201.6 | 126 | 12 | 0.00001 | 999999999.99999 |
| DN80 | 160/200/250/400/500 | 125 | 100 | 320 | 200 | 18 | 0.00001 | 999999999.99999 |
| DN100 | 160/200/250/400/500 | 200 | 160 | 512 | 320 | 28 | 0.00001 | 999999999.99999 |
| DN125 | 160/200/250/400/500 | 200 | 160 | 512 | 320 | 44 | 0.00001 | 999999999.99999 |
| DN150 | 160/200/250/400/500 | 312.5 | 250 | 800 | 500 | 64 | 0.00001 | 999999999.99999 |
| DN200 | 160/200/250/400/500 | 500 | 400 | 1280 | 800 | 113 | 0.00001 | 999999999.99999 |
| DN250 | 160/200/250/400/500 | 787.5 | 630 | 2016 | 1260 | 177 | 0.00001 | 999999999.99999 |
| DN300 | 160/200/250/400/500 | 1250 | 1000 | 3200 | 2000 | 254 | 0.00001 | 999999999.99999 |
| DN400 | 160/200/250/400/500 | 2000 | 1600 | 5120 | 3200 | 452 | 0.00001 | 999999999.99999 |
| DN500 | 160/200/250/400/500 | 3125 | 2500 | 8000 | 5000 | 707 | 0.00001 | 999999999.99999 |
| DN600 | 160/200/250/400/500 | 5000 | 4000 | 12800 | 8000 | 1018 | 0.00001 | 999999999.99999 |