Consult Now

Pad-Mounted Transformer (American Style)

Product Description

ZGS-Z(H)-12/0.4kV pad-mounted transformer (also known as American-style substation) is an important power supply unit in the distribution network, integrating high-voltage load switches and high-voltage fuses inside the transformer tank. The oil tank adopts a fully sealed structure, and the transformer oil inside has excellent insulation and heat dissipation performance. It features compact size, light weight, easy installation and maintenance, safety and reliability, and attractive appearance. It is widely used in outdoor power supply locations such as cities, residential areas, factories, mines, airports, docks, and railways.
ZGS-Z(H)-24/0.4kV pad-mounted transformer (also known as American-style substation) is an important power supply unit in the distribution network, integrating high-voltage load switches and high-voltage fuses inside the transformer tank. The oil tank adopts a fully sealed structure, and the transformer oil inside has excellent insulation and heat dissipation performance. It features compact size, light weight, easy installation and maintenance, safety and reliability, and attractive appearance. It is widely used in outdoor power supply locations such as cities, residential areas, factories, mines, airports, docks, and railways.
ZGS-Z·G-40.5 pad-mounted transformer for new energy is a factory-prefabricated outdoor compact power distribution equipment that integrates high-voltage switchgear, distribution transformer, and low-voltage distribution devices according to a specific wiring scheme. It is suitable for three-phase AC systems with a rated voltage of 40.5/0.4kV for power distribution and line use. It is applicable to industrial areas, residential areas, and special environments (such as high salt spray and high altitude).

3D 模型加载中...

Product Advantages

Pad-Mounted Transformer (American Style)

ZGS-Z(H)-12/0.4kV | 24/0.4kV | 40.5/0.69(0.8)kV
ItemParameter
Maximum Equipment Voltage24kV
Rated Capacity100~800kVA
Rated Voltage20/0.4kV
Rated Frequency50Hz
Vector GroupYyn0, Dyn11
Tap Range±2*2.5%
Number of Phases3
Insulation LevelLightning Impulse Withstand Voltage (Full Wave, Peak)
Power Frequency Withstand Voltage 1min55kV
Low Voltage Side Power Frequency Withstand Voltage 1min (Main Circuit)2.5kV
Phase-to-Phase and Phase-to-Ground 1min (Control and Metering Circuit)2.0kV
Insulation Heat Resistance ClassA
Enclosure MaterialSteel Plate / Galvanized Steel / Stainless Steel, etc.
IP RatingIP54
Outline DimensionsSelected based on transformer capacity and type
ItemParameter
Maximum Equipment Voltage24kV
Rated Capacity100~800kVA
Rated Voltage20/0.4kV
Rated Frequency50Hz
Vector GroupYyn0, Dyn11
Tap Range±2*2.5%
Number of Phases3
Insulation LevelLightning Impulse Withstand Voltage (Full Wave, Peak)
Power Frequency Withstand Voltage 1min55kV
Low Voltage Side Power Frequency Withstand Voltage 1min (Main Circuit)2.5kV
Phase-to-Phase and Phase-to-Ground 1min (Control and Metering Circuit)2.0kV
Insulation Heat Resistance ClassA
Enclosure MaterialSteel Plate / Galvanized Steel / Stainless Steel, etc.
IP RatingIP54
Outline DimensionsSelected based on transformer capacity and type
ItemParameter
Maximum Equipment Voltage40.5kV
Rated Capacity4000kVA
Rated Voltage38.5/0.69 (0.8) kV
Rated Current60/2886.8A
Rated Frequency50Hz
Short-Circuit Impedance7.00%
Maximum Pressure60kPa
Vector GroupDy11
Tap Range±2*2.5%
Number of Phases3
Full Wave200kV±3%
Chopped Wave220kV±3%
Insulation Heat Resistance ClassA
Enclosure MaterialSteel Plate / Galvanized Steel / Stainless Steel, etc.
IP RatingIP54
Outline DimensionsSelected based on transformer capacity and type

Success Stories

Product Qualification

Search

How Hexing Electrical Uses Cookies and Similar Technologies

To ensure the normal operation of the website, we sometimes store small data files called cookies on computers or mobile devices. A cookie is a plain text file stored on a computer or mobile device by a web server. The content of a cookie can only be retrieved or read by the server that created it. Each cookie is unique to your web browser or mobile application. Cookies typically contain identifiers, site names, and some numbers and characters. With the help of cookies, websites can store data such as user preferences or items in a shopping cart.

The purpose of Hexing Electrical enabling cookies is the same as that of most websites or internet service providers, which is to improve the user experience. With the help of cookies, websites can remember a user’s single visit (using session cookies) or multiple visits (using persistent cookies). With the help of cookies, websites can save settings such as language, font size, and other browsing preferences for a computer or mobile device. This means that users do not need to reconfigure their preferences each time they visit. If a website does not use cookies, it will treat the user as a new visitor every time they open a webpage. For example, if you log into a website and then go to another page, the website will not recognize you, and you will be logged out again. Hexing Electrical does not use cookies for any purpose other than those described in this policy. You can manage or delete cookies according to your preferences. For more details, please see AboutCookies.org. You can clear all cookies saved on your computer, and most web browsers have the function to block cookies. However, if you do this, you will need to change your user settings manually each time you visit our website. For more information on how to change browser settings, please visit the relevant help page of your browser.

In addition to cookies, we also use other similar technologies such as web beacons and pixel tags on our website. For example, emails sent to you by Hexing Electric may contain click URLs that link to content on the Hexing Electric website. If you click on such a link, Hexing Electric will track that click to help us understand your product and service preferences and improve customer service. A web beacon is typically a transparent image embedded in a website or email. With the help of pixel tags in emails, we can determine whether an email has been opened. If you do not wish your activity to be tracked in this way, you can unsubscribe from Hexing Electric’s mailing list at any time.

Your use of our website means you agree to the use of cookies, web beacons, and pixel tags as described above.