Consult Now

Commercial AC Charging Station

BUSH Series
Single-Phase: 2×7.3 kW, Three-Phase: 2×22 kW

The LIVOLTEK BUSH series AC charging stations are designed for public scenarios, featuring IP55 protection rating and optional floor-standing or wall-mounted installation, suitable for various indoor and outdoor environments.
All charging stations come with a built-in smart meter and support external meters or dynamic load balancing terminals, enabling integration with advanced energy systems in smart buildings and parking lots for more efficient energy management.

Datasheet

Flexible Application

  • Selectable charging gun or socket type
  • Integrated ISO 14443 RFID reader

Powerful Communication

  • Multiple Network Access Types
  • OCPP 1.6J Protocol (Free Upgrade to 2.0.1 Supported)
  • External Dynamic Load Response Support
  • Expandable POS Payment Terminal

Precise Monitoring

  • DLM Function with EV HUB for System-Level Dynamic Load Balancing
  • Built-in Energy Meter

User-Friendly Design

  • Integrated Leakage Current Monitoring (AC 30 mA + DC 6 mA)
  • IP55 Outdoor Protection Rating
  • 7-Inch High-Definition Display

Commercial AC Charging Station

BUSH 2S07 / BUSH 2S07 - Mini
Rated Power2*7.3 kW
Input Voltage Range230 Vac ±10%
Rated Output Current32 A
Charging InterfaceDual Socket (Optional)
Dimensions (W × H × D)Wall-mounted: 400 × 684 × 240 mm
Pole-mounted: 400 × 1484 × 240 mm
External CommunicationRS485 / CAN

Commercial AC Charging Station

BUSH 2C07 / BUSH 2C07 - Mini
Rated Power2*7.3 kW
Input Voltage Range230 Vac ±10%
Rated Output Current32 A
Charging InterfaceEquipped with 5 m dual-head charging cable
Dimensions (W × H × D)Wall-mounted: 400 × 684 × 240 mm
Pole-mounted: 400 × 1484 × 240 mm
External CommunicationRS485 / CAN

Commercial AC Charging Station

BUSH 2S22 / BUSH 2S22-mini
Rated Power2*22 kW
Input Voltage Range400 Vac ±10%
Rated Output Current32 A
Charging InterfaceDual-head socket (optional)
Dimensions (W × H × D)Wall-mounted: 400 × 684 × 240 mm
Pole-mounted: 400 × 1484 × 240 mm
External CommunicationRS485 / CAN

Commercial AC Charging Station

BUSH 2C22 / BUSH 2C22 - Mini
Rated Power2*22 kW
Input Voltage Range400 Vac ±10%
Rated Output Current32 A
Charging InterfaceEquipped with 5 m dual-head charging cable
Dimensions (W × H × D)Wall-mounted: 400 × 684 × 240 mm
Pole-mounted: 400 × 1484 × 240 mm
External CommunicationRS485 / CAN

Related Products

MF Series DC Charger

MF 60/90/120/150/180kW | MF 80/120/160/180/200/240kW
More

Residential AC Charging Station

R3B21E1E | R3B21B1E | R3B03E1E | R3B03B1E | R3B23E1E | R3B23B1E
More

Commercial AC Charging Station

B1U2ME2SOM0S B1U2ME2SOP0S B1U2ME2EOM5S| B1U2ME2EOP5S |B1U21E2SOM0S |B1U21E2SOP0S |B1U21E2EOM5S |B1U21E2EOP5S
More
Learn More About Products

Search

How Hexing Electrical Uses Cookies and Similar Technologies

To ensure the normal operation of the website, we sometimes store small data files called cookies on computers or mobile devices. A cookie is a plain text file stored on a computer or mobile device by a web server. The content of a cookie can only be retrieved or read by the server that created it. Each cookie is unique to your web browser or mobile application. Cookies typically contain identifiers, site names, and some numbers and characters. With the help of cookies, websites can store data such as user preferences or items in a shopping cart.

The purpose of Hexing Electrical enabling cookies is the same as that of most websites or internet service providers, which is to improve the user experience. With the help of cookies, websites can remember a user’s single visit (using session cookies) or multiple visits (using persistent cookies). With the help of cookies, websites can save settings such as language, font size, and other browsing preferences for a computer or mobile device. This means that users do not need to reconfigure their preferences each time they visit. If a website does not use cookies, it will treat the user as a new visitor every time they open a webpage. For example, if you log into a website and then go to another page, the website will not recognize you, and you will be logged out again. Hexing Electrical does not use cookies for any purpose other than those described in this policy. You can manage or delete cookies according to your preferences. For more details, please see AboutCookies.org. You can clear all cookies saved on your computer, and most web browsers have the function to block cookies. However, if you do this, you will need to change your user settings manually each time you visit our website. For more information on how to change browser settings, please visit the relevant help page of your browser.

In addition to cookies, we also use other similar technologies such as web beacons and pixel tags on our website. For example, emails sent to you by Hexing Electric may contain click URLs that link to content on the Hexing Electric website. If you click on such a link, Hexing Electric will track that click to help us understand your product and service preferences and improve customer service. A web beacon is typically a transparent image embedded in a website or email. With the help of pixel tags in emails, we can determine whether an email has been opened. If you do not wish your activity to be tracked in this way, you can unsubscribe from Hexing Electric’s mailing list at any time.

Your use of our website means you agree to the use of cookies, web beacons, and pixel tags as described above.